Top 12 Useful Cabling Tips for Network Cabling

Technology is progressing every single day! Regardless of the size of your business, services or products offered or volume of data handled, if you don’t have proper cabling, it can lead to heat retention, untimely hardware, failure and maintenance issues, etc. So, just by investing a little more time in proper planning and organization, you won’t have to worry anymore in the future.

In order to match the pace with rapidly evolving cyberspace, you need to have proper cabling installation. With it, you will have a flexible, scalable, and adaptable network to meet your present and future data needs. It will also minimize the potential poor network performance, Downtimes and the risk of being outdated. For such services in the UK, you can look for cabling installation providers.

Here are some tips to keep your network cabling organized to ensure you get network reliability and cable longevity.

  • Cable Length Matters

According to the EIA/TIA standard, you should have a cable of a maximum length of 100 meters, including patch leads. In case you are using 10-meter patch leads at each end, your horizontal line should run only 80 meters. If you have 20-meter patch leads, you can have only 60 meters in the wall.

  • Long Patch Leads can be a Bad Idea

Well, in the fibre and copper cable installations case, things can’t work with thought it might work. Suppose you wish to avoid the poor connection to hinder your smooth work. In that case, it’s high time to get the right quality cable and connectors and a well-executed cabling system since the electrical signal will degrade less in that environment. Cheap installs are prone to more problems. Long patch leads can work fine in your office, but it is a bad idea in some places. A 150-meter long cable probably won’t work reliably.

  • Overloaded Cable Trays

When trying to achieve a hassle-free network connection, cable trays should not be overloaded. Suspended cable trays are either mounted to either ceiling or to support from a rack underneath. If in case they become sober, they can fall off the wall/ceiling etc. One loss is the cost, and the other is the work.

  • Leave Space to Remove Unused Cables

If your network cabling has started to look like a big ball of spaghetti has exploded, you need to know that it is a big problem in terms of safety, and it can also lead to bad operational practice. With this, people also become fearful of removing cables from trays to avoid the network issues that come your way! 

  • Crushed Cables in Overloaded Cable Trays

The cables lying at the bottom of the trays can be crushed by cables’ weight, especially in Cat6 cabling, which is thicker and heavier than previously used copper cabling. The crushed cables will have a degrade signal propagation.

  • Hanging Cables will Stretch

Hanging cables can be affected by gravity. When cables are turned on a rack, gravity induces physical stress on the copper core, making prone to stretch and distort over time. Also, bear in mind that longer patch lead is heavier and hard in terms of stress on the cable. Over some time, it will create signal degradation and latter intermittent failures. Patch management is not only a way to keep your rack tidy, but it is mechanically practical too.

  • Don’t Pull Too Hard

When you wish to keep the cableway from any stress and damage, you don’t want to pull the cable very hard. Mind that stressing the copper core can cause stretching/thinning of the wire can affect the signal performance. In some cases, it can cause unwinding of the twists in the sheath. Therefore, networking experts suggest applying 110Newtons as maximum draw force during installation. Make sure your cabling manufacturer should ensure that cables that can withstand this stress. It means you should steer clear from cheap quality cables. Ask your cabling installation services in the UK to use a force meter when pulling cable to category six standards to ensure that pulling strength doesn’t exceed the maximum pressure limit of 100Newton.

  • Electrical Conduits not Good for Data Cabling

Transmission boxes and electrical conduits both don’t work with Category 6 or CAT6 cable because the radii at the right angle in copper Cat6 cable are smaller than the permitted bend result. Bend damage can alter the cable kinking changes, core stress, and leads to signal degradation.

  • Less Copper

Low-quality cables have lower than standard diameter copper cores, causing signal loss and bad imperfect signal propagation. When non-standard copper cores are paired to standard cores, it produces more interference. Why? Because impedance mismatch results in signal reflections. Besides, narrow-diameter hearts are also physically weaker and tend to stretch or snap in the future resulting in failure.

  • Cheap Patch Leads

If you are not looking to have any kind of disturbance in your network connection, then you shouldn’t use cheap patch cords. Again cheaper cables don’t match the standard, which causes signal degradation. Other factors to cut down on manufacturing costs are:

  • poor quality control over twist ratios
  • poor packaging
  • non-pure copper cores
  • substandard sheathing
  • Keep Away from Power Cables

If you are not aware that copper cables, when run parallel to electrical cables, act like transformers or inductors. They also induce 50-60 Hz current noise from the electrical cord. Therefore, it is essential to keep the distance between data and power cables as much as possible. For professional help, prefer cabling installation services in the UK and get rid of every future issue.

  • Keep Away from Electrical Interference Sources

    Other sources that cause interference are fluoro light in your data center. So, in your data center, do not use fluoro light, instead use LEDs or any other low power lighting for generating less interference. Also, in an air conditioning room, keep the motors away from data cabling. In any cabling structure, the weakest link impacts the performance of your entire cable system. So be careful while installing the cable system at any facility

Posted: 28,09,2020